Brogen Auxiliary Power Controller BG-AUX-OEAPC001

  • Integrated DC/DC, DC/AC, and PDU functions
  • Wide HV input voltage range
  • IP67-rated protection
  • CAN 2.0 communication
  • Compact liquid-cooled design
Facebook
X
LinkedIn
Email

Select the configuration that matches your application requirements. All configurations accept 250–750 VDC high-voltage input. Contact our team for a customised solution.

Configuration DC/AC ×1 DC/AC ×2 DC/DC PDU Key parameters
Single DC/AC
Oil pump or air pump
Output power 5.5 kW
HV input 250–750 VDC
AC output 220 VAC or 380 VAC
Send inquiry →
Single DC/DC
On-board battery charging
Output power 1.5 kW or 3 kW
HV input 250–750 VDC
DC output 14 VDC or 27.5 VDC
Send inquiry →
Two-in-one
DC/AC + DC/DC
DC/AC output 5.5 kW, 220 / 380 VAC
DC/DC output 1.5 kW or 3 kW
HV input 250–750 VDC
Send inquiry →
Two-in-one
DC/AC + DC/AC
DC/AC output 5.5 kW × 2, 220 / 380 VAC
HV input 250–750 VDC
Drives Oil pump + air pump
Send inquiry →
Three-in-one
DC/AC + DC/AC + DC/DC
DC/AC output 5.5 kW × 2, 220 / 380 VAC
DC/DC output 1.5 kW or 3 kW
HV input 250–750 VDC
Send inquiry →
Four-in-one
DC/AC + DC/AC + DC/DC + PDU
DC/AC output 5.5 kW × 2, 220 / 380 VAC
DC/DC output 3 kW, 27.5 VDC
HV input 350–750 VDC
Send inquiry →
Included
Not included
DC/AC MODULE
Parameter Value
HV Input Voltage250–750 VDC
AC Output Voltage220 VAC or 380 VAC
Rated Output Power5.5 kW per channel
Peak Output Power7.5 kW per channel
Rated Output Current13 A
Peak Output Current19 A (60 s)
Overload Capacity150% / 60 s · 180% / 10 s · 200% / 0.5 s
Maximum Efficiency≥ 93%
Over-voltage Protection720 VDC
Under-voltage Protection400 VDC
Over-current Protection19 A
Over-temperature Protection80 °C
CommunicationCAN 2.0
DC/DC MODULE
Parameter Value
HV Input Voltage250–750 VDC
Rated Output Voltage14 VDC or 27.5 VDC
Rated Output Power1.5 kW or 3 kW
Peak Output Power3.6 kW
Rated Output Current107 A (14 V) / 110 A (27.5 V)
Peak Output Current128 A / 125 A (60 s)
Maximum Efficiency≥ 96%
Voltage Regulation Accuracy± 1%
Output Ripple & Noise300 mVp-p
Over-voltage Protection760–810 VDC
Under-voltage Protection270–290 VDC
Over-temperature Protection85 °C
CommunicationCAN 2.0
PDU
Parameter Value
Main Contactor Rating600 A / 1,000 V
Branch Contactor Rating50 A / 750 V
Fuse Rating40–80 A / 750 V
FunctionsA/C compressor, PTC heater ×2, electric defrost
Contactor Welding DetectionYes
GENERAL
Parameter Value
LV Supply Voltage12 / 24 VDC
Operating Temperature−40 °C to +85 °C
Storage Temperature−40 °C to +105 °C
Operating Humidity5–95% RH
Operating Altitude≤ 3,000 m
Cooling MethodAir-cooled or liquid-cooled
Coolant50% ethylene glycol + 50% water (liquid-cooled)
Protection RatingIP67
CommunicationCAN 2.0
Installation OrientationHorizontal only
Grounding Requirement≥ 6 mm² ground wire, impedance ≤ 1 Ω
CertificationGB/T 18488.1-2006

Send an Inquiry


    Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
    • Image
    • SKU
    • Rating
    • Price
    • Stock
    • Availability
    • Add to cart
    • Description
    • Content
    • Weight
    • Dimensions
    • Additional information
    Click outside to hide the comparison bar
    Compare
    Compare ×
    Let's Compare! Continue shopping