Auxiliary Power Controller BG-AUX-OEAPC001

  • Integrated DC/DC, DC/AC, and PDU functions
  • Wide HV input voltage range
  • IP67-rated protection
  • CAN 2.0 communication
  • Compact liquid-cooled design
Facebook
X
LinkedIn
Email

Select the configuration that matches your application requirements. All configurations accept 250–750 VDC high-voltage input. Contact our team for a customised solution.

Configuration DC/AC ×1 DC/AC ×2 DC/DC PDU Key parameters
Single DC/AC
Oil pump or air pump
Output power 5.5 kW
HV input 250–750 VDC
AC output 220 VAC or 380 VAC
Send inquiry →
Single DC/DC
On-board battery charging
Output power 1.5 kW or 3 kW
HV input 250–750 VDC
DC output 14 VDC or 27.5 VDC
Send inquiry →
Two-in-one
DC/AC + DC/DC
DC/AC output 5.5 kW, 220 / 380 VAC
DC/DC output 1.5 kW or 3 kW
HV input 250–750 VDC
Send inquiry →
Two-in-one
DC/AC + DC/AC
DC/AC output 5.5 kW × 2, 220 / 380 VAC
HV input 250–750 VDC
Drives Oil pump + air pump
Send inquiry →
Three-in-one
DC/AC + DC/AC + DC/DC
DC/AC output 5.5 kW × 2, 220 / 380 VAC
DC/DC output 1.5 kW or 3 kW
HV input 250–750 VDC
Send inquiry →
Four-in-one
DC/AC + DC/AC + DC/DC + PDU
DC/AC output 5.5 kW × 2, 220 / 380 VAC
DC/DC output 3 kW, 27.5 VDC
HV input 350–750 VDC
Send inquiry →
Included
Not included
DC/AC MODULE
Parameter Value
HV Input Voltage250–750 VDC
AC Output Voltage220 VAC or 380 VAC
Rated Output Power5.5 kW per channel
Peak Output Power7.5 kW per channel
Rated Output Current13 A
Peak Output Current19 A (60 s)
Overload Capacity150% / 60 s · 180% / 10 s · 200% / 0.5 s
Maximum Efficiency≥ 93%
Over-voltage Protection720 VDC
Under-voltage Protection400 VDC
Over-current Protection19 A
Over-temperature Protection80 °C
CommunicationCAN 2.0
DC/DC MODULE
Parameter Value
HV Input Voltage250–750 VDC
Rated Output Voltage14 VDC or 27.5 VDC
Rated Output Power1.5 kW or 3 kW
Peak Output Power3.6 kW
Rated Output Current107 A (14 V) / 110 A (27.5 V)
Peak Output Current128 A / 125 A (60 s)
Maximum Efficiency≥ 96%
Voltage Regulation Accuracy± 1%
Output Ripple & Noise300 mVp-p
Over-voltage Protection760–810 VDC
Under-voltage Protection270–290 VDC
Over-temperature Protection85 °C
CommunicationCAN 2.0
PDU
Parameter Value
Main Contactor Rating600 A / 1,000 V
Branch Contactor Rating50 A / 750 V
Fuse Rating40–80 A / 750 V
FunctionsA/C compressor, PTC heater ×2, electric defrost
Contactor Welding DetectionYes
GENERAL
Parameter Value
LV Supply Voltage12 / 24 VDC
Operating Temperature−40 °C to +85 °C
Storage Temperature−40 °C to +105 °C
Operating Humidity5–95% RH
Operating Altitude≤ 3,000 m
Cooling MethodAir-cooled or liquid-cooled
Coolant50% ethylene glycol + 50% water (liquid-cooled)
Protection RatingIP67
CommunicationCAN 2.0
Installation OrientationHorizontal only
Grounding Requirement≥ 6 mm² ground wire, impedance ≤ 1 Ω
CertificationGB/T 18488.1-2006
4 in 1 detail2
aux controller 4in1 detail 4
Company Profile new
Product Profile new
Brogen Team new
Brogen Factory new

Send an Inquiry


    Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
    • Image
    • SKU
    • Rating
    • Price
    • Stock
    • Availability
    • Add to cart
    • Description
    • Content
    • Weight
    • Dimensions
    • Additional information
    Click outside to hide the comparison bar
    Compare
    Compare ×
    Let's Compare! Continue shopping